Lovibond 511251BT DPD No. 3 Nessler Tablet Reagents | Total Chlorine Testing | Pack of 250 Tablets
Description
Lovibond® DPD No. 3 Nessler Tablet Reagents 511251BT – Pack of 250
Product Overview
Lovibond® DPD No. 3 Nessler Tablet Reagents 511251BT are professional water-testing reagents used for the determination of total chlorine in water using compatible Lovibond® test kits, comparators, colorimeters and spectrophotometers.
DPD No. 3 is added to a water sample after the free chlorine measurement with DPD No. 1. The reagent enables determination of total chlorine; combined chlorine can subsequently be determined from the difference between total chlorine and free chlorine.
Pack Size: 250 Tablets
Product Code: 511251BT
Reagent: DPD No. 3 Nessler
Primary Application: Total Chlorine Testing
Brand: Lovibond®
Key Features
- Genuine Lovibond® DPD No. 3 Nessler reagent tablets
- 250 tablets per pack
- Designed for total chlorine determination
- Suitable for compatible Lovibond® test kits and photometric systems
- Designed for use with the Nessleriser system
- Pre-dosed tablet format for convenient reagent addition
- Easy and practical handling
- Consistent reagent dosing
- Individual blister-style tablet packaging
- Suitable for routine professional water analysis
- Suitable for laboratory and water-treatment applications
What Is DPD No. 3 Used For?
DPD No. 3 is used in the DPD chlorine testing method to determine total chlorine.
In a typical procedure:
- The water sample is first tested for free chlorine using DPD No. 1.
- DPD No. 3 is then added to the same sample.
- The reagent reacts with the appropriate chlorine species to produce the measurement response.
- The resulting value is used to determine total chlorine.
- The difference between total chlorine and free chlorine can be used to calculate combined chlorine.
This makes DPD No. 3 an important reagent for chlorine monitoring in water-treatment and recreational-water applications.
Applications
Ideal for:
- Swimming pool water testing
- Spa and recreational water testing
- Drinking-water analysis
- Water-treatment plants
- Industrial water monitoring
- Environmental water testing
- Laboratory water analysis
- Chlorination monitoring
- Residual disinfectant testing
- Quality-control laboratories
- Professional pool maintenance
Product Specifications
| Specification | Details |
|---|---|
| Brand | Lovibond® |
| Product Type | DPD No. 3 Nessler Reagent Tablets |
| Product Code | 511251BT |
| Reagent | DPD No. 3 Nessler |
| Parameter | Total Chlorine |
| Form | Tablet |
| Pack Size | 250 Tablets |
| Method | DPD Colorimetric Method |
| Application | Water Quality Analysis |
| Compatible Equipment | Compatible Lovibond® test kits, colorimeters & spectrophotometers |
| Packaging | Blister |
| Intended Use | Professional Water Testing |
Fisher Scientific identifies 511251BT as the Lovibond supplier number for the 250-tablet DPD No. 3 Nessler pack.
Measurement Ranges
Published Lovibond method information for DPD No. 3 Nessler includes total-chlorine methods covering ranges such as:
- 0.01–0.10 mg/L Cl₂
- 0.02–0.20 mg/L Cl₂
- 0.05–0.50 mg/L Cl₂
- 0.10–1.00 mg/L Cl₂
The applicable range depends on the specific Lovibond® test method and instrument being used.
Compatible Equipment
The tablets are intended for use with compatible Lovibond®:
- Test kits
- Comparators
- Colorimeters
- Spectrophotometers
- Nessleriser systems
Always select the appropriate DPD No. 3 Nessler procedure specified for your particular instrument or test kit.
Tablet Packaging
The BT designation identifies the newer blister-style packaging. Each tablet is individually protected within the blister packaging, allowing the tablet to be dispensed directly into the sample while minimizing handling.
Advantages
Accurate Reagent Dosing
Pre-dosed tablets provide a convenient and consistent quantity of reagent for each test.
Easy Handling
The tablet format eliminates the need to measure liquid reagent for routine analysis.
Convenient Storage
Individual blister packaging helps protect the reagent tablets and makes individual testing convenient.
Professional Water Testing
Suitable for laboratories, water-treatment facilities, pool professionals and other users performing regular chlorine analysis.
High-Volume Pack
The 250-tablet pack is well suited to laboratories and facilities with frequent testing requirements.
What's Included
1 × Lovibond® DPD No. 3 Nessler Reagent Tablets – 250 Tablets
Product Code: 511251BT
Important Usage & Safety Information
Use the reagent tablets only according to the instructions supplied with the compatible Lovibond® test kit or instrument.
For reliable results:
- Follow the prescribed test procedure.
- Use clean sample cells and testing equipment.
- Avoid contamination of samples and reagents.
- Use the correct DPD No. 3 Nessler method for the instrument.
- Store the reagent according to the manufacturer's instructions.
- Check the package for batch and expiry information.
Safety: Published supplier information identifies the formulation as containing potassium iodide and carries a hazardous-product classification. Handle according to the supplied safety documentation and applicable laboratory safety procedures.
Ideal For
Water Testing Laboratories | Swimming Pools | Spas | Water Treatment Plants | Drinking Water Testing | Environmental Laboratories | Industrial Water Treatment | Research Laboratories | Quality Control
Shipping Info
We partner with premium logistics networks via Shiprocket to ensure your laboratory instruments and chemical indicators arrive safely, securely, and professionally packaged. Shipping timelines depend on the transit tier selected at checkout.
National Deliveries (Within India)
- Rush Delivery: Less than 2 business days
- Express Delivery: 2 to 5 business days
- Standard Delivery: Greater than 5 business days.