HACH DR 3900 Laboratory Spectrophotometer | 320–1100 nm | Water & Wastewater Analysis | Color Touchscreen
HACH DR 3900 Laboratory Spectrophotometer | 320–1100 nm | Water & Wastewater Analysis | Color Touchscreen

HACH DR 3900 Laboratory Spectrophotometer | 320–1100 nm | Water & Wastewater Analysis | Color Touchscreen

In Stock
🚚
Shipping Timeline
3-4 Weeks
Sale priceRs. 740,000.00 Regular priceRs. 799,999.00
Save Rs. 59,999.00
Inclusive of GST: 18%
SKU: HACH DR3900
Categories : Benchtop Meters
Quantity
Description

HACH DR 3900 SPECTROPHOTOMETER

Smart Technology. Consistently Accurate Results.

The HACH DR 3900 is a laboratory-grade visible-spectrum spectrophotometer designed for reliable and repeatable water analysis. It combines a broad 320–1100 nm wavelength range, automatic wavelength selection, a color touchscreen interface and a large library of pre-programmed water-analysis methods.

Key Features

  • Visible-spectrum spectrophotometer: 320–1100 nm
  • Split/reference-beam optical system for stable measurements
  • 7-inch TFT color touchscreen with 800 × 480 WVGA resolution
  • Automatic wavelength calibration and selection
  • Over 220 pre-programmed water-analysis methods; the current Hach India specification lists more than 240 methods for the non-RFID configuration.
  • 100 user-programmable methods
  • Measures transmittance, absorbance and concentration, with wavelength scanning
  • Compatible with multiple sample cell formats
  • 2,000-result data storage including result, date, time, sample ID and user ID
  • USB and Ethernet connectivity
  • Available in configurations with or without RFID technology
  • Designed for routine laboratory water and wastewater analysis

Technical Specifications

Specification Details
Product HACH DR 3900 Spectrophotometer
Instrument Type Benchtop Visible-Spectrum Spectrophotometer
Wavelength Range 320–1100 nm
Wavelength Resolution 1 nm
Wavelength Accuracy ±1.5 nm, 340–900 nm
Wavelength Reproducibility ±0.1 nm
Spectral Bandwidth 5 nm
Wavelength Calibration Automatic
Wavelength Selection Automatic
Optical System Spectral reference beam
Light Source Gas-filled tungsten lamp
Photometric Range ±3.0 Abs, 340–900 nm
Photometric Accuracy 5 mAbs at 0.0–0.5 Abs; 1% at 0.5–2.0 Abs
Photometric Linearity <0.5% up to 2 Abs
Stray Light <0.1% T at 340 nm with NaNO₂
Display 7-inch TFT color touchscreen
Display Resolution 800 × 480 pixels (WVGA)
Data Storage 2,000 measured values
User Programs 100
Pre-programmed Methods 220+ / configuration-dependent
Operating Modes Transmittance, Absorbance, Concentration, Scanning
Sample Cell Compatibility 10 mm, 50 mm and 1-inch rectangular; 13 mm, 16 mm and 1-inch round
Beam Height 10 mm
Interfaces 2 × USB Type-A, USB Type-B, Ethernet; RFID on applicable version
Operating Temperature 10–40°C
Storage Temperature Up to approximately −40 to 60°C, configuration/specification dependent
Enclosure Rating IP40
Power Supply 110–240 V AC, 50/60 Hz, external supply
Dimensions (H × W × D) 151 × 350 × 255 mm
Weight 4.2 kg

Specifications are based on Hach's current product information; exact accessories, warranty and RFID features can vary by configuration/part number.

Water Analysis Applications

The DR 3900 is designed for a wide range of laboratory water and wastewater testing applications, including:

  • Ammonia
  • COD
  • Phosphate
  • Nitrate
  • Nitrite
  • Chlorine
  • Chloride
  • Alkalinity
  • Aluminum
  • Bromine
  • Boron
  • Iron
  • Manganese
  • Sulphate
  • Silica
  • Total nitrogen
  • Total phosphorus
  • And many other Hach water-analysis parameters

Hach specifically positions the DR 3900 for routine laboratory water analysis and provides extensive pre-programmed methods for water-quality testing.

Smart Data Management

The instrument can store up to 2,000 measurement records, including the measurement result, date, time, sample ID and user ID. USB and Ethernet interfaces support convenient data transfer and laboratory workflow integration.

RFID Technology – Applicable Models

The RFID-equipped version provides additional workflow functionality for Hach TNTplus chemistry, including method identification, sample identification and certificate-of-analysis information. Hach also offers the DR 3900 without RFID technology.

Compatible Sample Cells

The DR 3900 supports a variety of cell formats, including:

  • 10 mm rectangular cells
  • 50 mm rectangular cells
  • 1-inch rectangular cells
  • 13 mm round cells
  • 16 mm round cells
  • 1-inch round cells

This flexibility makes the instrument suitable for different Hach test methods and sample volumes.

What's Included

Depending on the selected configuration, the standard package can include:

  • HACH DR 3900 Spectrophotometer
  • Adapter for 1-inch round and 1 cm rectangular/AccuVac cells
  • Sample cells as applicable to the configuration
  • Light shield
  • Dust cover
  • User documentation/manual
  • External benchtop power supply
  • Power cords

Please verify the exact contents against the selected HACH part number before purchase, as package contents differ between configurations.

Ideal For

Water Testing Laboratories | Wastewater Treatment Plants | Drinking Water Laboratories | Environmental Laboratories | Industrial Water Treatment | Research Laboratories | Municipal Water Testing | Food & Beverage Water Analysis | Pharmaceutical Utilities | Chemical Industries

Shipping Info

We partner with premium logistics networks via Shiprocket to ensure your laboratory instruments and chemical indicators arrive safely, securely, and professionally packaged. Shipping timelines depend on the transit tier selected at checkout.

National Deliveries (Within India)

  1. Rush Delivery: Less than 2 business days
  2. Express Delivery: 2 to 5 business days
  3. Standard Delivery: Greater than 5 business days.

Related Products