{"product_id":"milwaukee-cd600-digital-total-dissolved-solids-tds-pen-0-1990-ppm-range-10-ppm-resolution-2-fs-accuracy-automatic-temperature-compensation-atc","title":"Milwaukee CD600 Digital Total Dissolved Solids (TDS) Pen | 0–1990 ppm Range | 10 ppm Resolution | ±2% FS Accuracy | Automatic Temperature Compensation (ATC)","description":"\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eShort Description\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eMilwaukee CD600\u003c\/strong\u003e is a compact digital TDS meter designed for quick measurement of Total Dissolved Solids in water and aqueous solutions. It measures directly in \u003cstrong\u003eppm\u003c\/strong\u003e, features \u003cstrong\u003eautomatic temperature compensation from 5–50°C\u003c\/strong\u003e, and offers simple one-point manual calibration. It is suitable for hydroponics, aquariums, water conditioning, filtration checks, horticulture and general water-quality testing. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTDS measurement:\u003c\/strong\u003e 0–1990 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±2% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Temperature Compensation (ATC):\u003c\/strong\u003e 5–50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Simple 1-point manual calibration using a trimmer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Easy-to-read digital LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact pen-style design\u003c\/strong\u003e for portable testing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory calibrated\u003c\/strong\u003e and can be recalibrated when required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery powered:\u003c\/strong\u003e 4 × 1.5 V alkaline batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery life:\u003c\/strong\u003e Approximately 300 hours according to the current Milwaukee manual \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for quick TDS measurements in water and nutrient solutions \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMilwaukee Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCD600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital TDS Pen \/ Pocket TDS Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–1990 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual, 1-point via trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration Solution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10032B, 1382 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATC Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–50°C; up to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 × 1.5 V alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 300 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 × 30 × 24 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 85 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSpecifications above are based primarily on Milwaukee's current user manual; some older\/current retailer pages report slightly different dimensions and battery-life figures, so the manufacturer's manual is the preferred reference. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Milwaukee CD600 is suitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e💧 Drinking and process-water screening\u003c\/li\u003e\n\u003cli\u003e🚰 Water filtration monitoring\u003c\/li\u003e\n\u003cli\u003e🌱 Hydroponics and nutrient-solution testing\u003c\/li\u003e\n\u003cli\u003e🌿 Horticulture and agriculture\u003c\/li\u003e\n\u003cli\u003e🐠 Aquarium and aquaculture water testing\u003c\/li\u003e\n\u003cli\u003e🧪 Laboratory and educational applications\u003c\/li\u003e\n\u003cli\u003e🏊 Pool and water-conditioning checks\u003c\/li\u003e\n\u003cli\u003e💦 General water-quality monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHow to Use\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eRemove the protective cap.\u003c\/li\u003e\n\u003cli\u003eSwitch on the CD600.\u003c\/li\u003e\n\u003cli\u003eImmerse the probe into the sample up to the recommended immersion level.\u003c\/li\u003e\n\u003cli\u003eGently stir the solution.\u003c\/li\u003e\n\u003cli\u003eWait for the reading to stabilize.\u003c\/li\u003e\n\u003cli\u003eRead the TDS value displayed in ppm.\u003c\/li\u003e\n\u003cli\u003eRinse the probe with fresh tap or DI water after use to minimize deposits. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCalibration\u003c\/h3\u003e\n\u003cp\u003eThe CD600 is factory calibrated and provides \u003cstrong\u003e1-point manual calibration\u003c\/strong\u003e through the calibration trimmer. Milwaukee specifies \u003cstrong\u003eM10032B 1382 ppm TDS calibration solution\u003c\/strong\u003e for the CD600. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cp\u003eTypical CD600 supply includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMilwaukee CD600 Digital TDS Tester\u003c\/li\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003cli\u003eCalibration screwdriver\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eInstruction\/user manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMilwaukee's product documentation specifically states that the CD600 is supplied with a protective cap, calibration screwdriver, batteries and instructions. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTDS to EC Conversion\u003c\/h3\u003e\n\u003cp\u003eTDS readings can be approximately related to electrical conductivity depending on the conversion scale used. Milwaukee gives examples including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 scale:\u003c\/strong\u003e 1 ppm ≈ 2 µS\/cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e442 scale:\u003c\/strong\u003e 1 ppm ≈ 1.43 µS\/cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are approximate conversions, not universal constants, because the relationship depends on the TDS conversion factor used. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eAdvantages\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCompact \u0026amp; Portable:\u003c\/strong\u003e Pen-style construction makes the meter convenient for field and routine testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFast TDS Testing:\u003c\/strong\u003e Direct ppm measurement provides a quick indication of dissolved-solids concentration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Temperature Compensation:\u003c\/strong\u003e ATC helps compensate for temperature-related changes during measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSimple Calibration:\u003c\/strong\u003e One-point manual calibration makes routine maintenance straightforward.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWide Practical Range:\u003c\/strong\u003e The 0–1990 ppm range is particularly suited to many hydroponic, aquarium, horticultural and general water-conditioning applications. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"MILWAUKEE","offers":[{"title":"Default Title","offer_id":47309046710445,"sku":"MILWAUKEE CD600","price":2800.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/7666\/9357\/files\/rn-image_picker_lib_temp_7a769cd0-ad76-4170-859c-3c9206b9497d.webp?v=1787635043","url":"https:\/\/rinstruments.com\/products\/milwaukee-cd600-digital-total-dissolved-solids-tds-pen-0-1990-ppm-range-10-ppm-resolution-2-fs-accuracy-automatic-temperature-compensation-atc","provider":"Rinstruments","version":"1.0","type":"link"}