{"product_id":"lutron-pms-714-digital-soil-moisture-meter-soil-moisture-tester-0-50-moisture-content-probe-type","title":"Lutron PMS-714 Digital Soil Moisture Meter | Soil Moisture Tester | 0–50% Moisture Content | Probe Type","description":"\u003ch1 data-section-id=\"1j2qlle\" data-start=\"386\" data-end=\"405\" class=\"PDq2pG_selectionAnchorContainer\"\u003eShort Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"407\" data-end=\"989\"\u003eThe \u003cstrong data-start=\"411\" data-end=\"429\"\u003eLutron PMS-714\u003c\/strong\u003e is a professional \u003cstrong data-start=\"448\" data-end=\"479\"\u003edigital soil moisture meter\u003c\/strong\u003e designed to accurately measure the moisture content of soil and similar materials. Featuring a durable two-pin electrode probe, microprocessor-controlled circuitry, and a clear LCD display, it provides fast and reliable moisture readings from \u003cstrong data-start=\"723\" data-end=\"736\"\u003e0% to 50%\u003c\/strong\u003e. Ideal for agriculture, horticulture, landscaping, greenhouses, research laboratories, and environmental monitoring, the PMS-714 offers simple operation and dependable performance for both field and laboratory use. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"991\" data-end=\"994\"\u003e\n\u003ch1 data-section-id=\"u0ybrq\" data-start=\"996\" data-end=\"1010\"\u003eKey Features\u003c\/h1\u003e\n\u003cul data-start=\"1012\" data-end=\"1439\"\u003e\n\u003cli data-section-id=\"68x145\" data-start=\"1012\" data-end=\"1054\"\u003eProfessional Digital Soil Moisture Meter\u003c\/li\u003e\n\u003cli data-section-id=\"16x1yhx\" data-start=\"1055\" data-end=\"1106\"\u003eMeasures Soil Moisture Content from \u003cstrong data-start=\"1093\" data-end=\"1106\"\u003e0% to 50%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qjy9dx\" data-start=\"1107\" data-end=\"1142\"\u003ePrecision Two-Pin Electrode Probe\u003c\/li\u003e\n\u003cli data-section-id=\"7g9zfo\" data-start=\"1143\" data-end=\"1181\"\u003eHigh Accuracy Microprocessor Circuit\u003c\/li\u003e\n\u003cli data-section-id=\"1bzgpdw\" data-start=\"1182\" data-end=\"1201\"\u003eLarge LCD Display\u003c\/li\u003e\n\u003cli data-section-id=\"150u96p\" data-start=\"1202\" data-end=\"1229\"\u003eFast Measurement Response\u003c\/li\u003e\n\u003cli data-section-id=\"itsx1x\" data-start=\"1230\" data-end=\"1250\"\u003eData Hold Function\u003c\/li\u003e\n\u003cli data-section-id=\"1oosgcw\" data-start=\"1251\" data-end=\"1274\"\u003eLow Battery Indicator\u003c\/li\u003e\n\u003cli data-section-id=\"1ltbs79\" data-start=\"1275\" data-end=\"1305\"\u003eCompact \u0026amp; Lightweight Design\u003c\/li\u003e\n\u003cli data-section-id=\"olxhq8\" data-start=\"1306\" data-end=\"1335\"\u003eDurable ABS Plastic Housing\u003c\/li\u003e\n\u003cli data-section-id=\"8tboxl\" data-start=\"1336\" data-end=\"1361\"\u003eEasy One-Hand Operation\u003c\/li\u003e\n\u003cli data-section-id=\"iz2aek\" data-start=\"1362\" data-end=\"1408\"\u003eSuitable for Field \u0026amp; Laboratory Applications\u003c\/li\u003e\n\u003cli data-section-id=\"9i69er\" data-start=\"1409\" data-end=\"1439\"\u003ePortable and Battery Powered\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1441\" data-end=\"1444\"\u003e\n\u003ch1 data-section-id=\"c3mln3\" data-start=\"1446\" data-end=\"1460\"\u003eApplications\u003c\/h1\u003e\n\u003cp data-start=\"1462\" data-end=\"1472\"\u003eIdeal for:\u003c\/p\u003e\n\u003cul data-start=\"1474\" data-end=\"1699\"\u003e\n\u003cli data-section-id=\"13ecb4p\" data-start=\"1474\" data-end=\"1487\"\u003eAgriculture\u003c\/li\u003e\n\u003cli data-section-id=\"1ao2edo\" data-start=\"1488\" data-end=\"1502\"\u003eHorticulture\u003c\/li\u003e\n\u003cli data-section-id=\"1pcw85g\" data-start=\"1503\" data-end=\"1516\"\u003eGreenhouses\u003c\/li\u003e\n\u003cli data-section-id=\"aasl4t\" data-start=\"1517\" data-end=\"1534\"\u003ePlant Nurseries\u003c\/li\u003e\n\u003cli data-section-id=\"8eca0e\" data-start=\"1535\" data-end=\"1548\"\u003eLandscaping\u003c\/li\u003e\n\u003cli data-section-id=\"1crjcaq\" data-start=\"1549\" data-end=\"1576\"\u003eSoil Testing Laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"iesvbw\" data-start=\"1577\" data-end=\"1603\"\u003eEnvironmental Monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"nyea0x\" data-start=\"1604\" data-end=\"1627\"\u003eIrrigation Management\u003c\/li\u003e\n\u003cli data-section-id=\"1nb637f\" data-start=\"1628\" data-end=\"1649\"\u003eResearch Institutes\u003c\/li\u003e\n\u003cli data-section-id=\"10gwr6y\" data-start=\"1650\" data-end=\"1664\"\u003eUniversities\u003c\/li\u003e\n\u003cli data-section-id=\"n4bjwz\" data-start=\"1665\" data-end=\"1676\"\u003eGardening\u003c\/li\u003e\n\u003cli data-section-id=\"1ov3bm4\" data-start=\"1677\" data-end=\"1699\"\u003eSoil Science Studies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1701\" data-end=\"1704\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"1706\" data-end=\"1732\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"6wsbrs\" data-start=\"1734\" data-end=\"1762\"\u003eSoil Moisture Measurement\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1764\" data-end=\"2024\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1764\" data-end=\"1793\"\u003e\n\u003ctr data-start=\"1764\" data-end=\"1793\"\u003e\n\u003cth data-start=\"1764\" data-end=\"1776\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1776\" data-end=\"1793\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1824\" data-end=\"2024\"\u003e\n\u003ctr data-start=\"1824\" data-end=\"1898\"\u003e\n\u003ctd data-start=\"1824\" data-end=\"1846\" data-col-size=\"sm\"\u003e\u003cstrong\u003eMeasuring Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1846\" data-end=\"1898\" data-col-size=\"md\"\u003eConductivity Measurement using Two-Pin Electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1899\" data-end=\"1951\"\u003e\n\u003ctd data-start=\"1899\" data-end=\"1917\" data-col-size=\"sm\"\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1917\" data-end=\"1951\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1919\" data-end=\"1949\"\u003e0.0 to 50.0% Soil Moisture\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1952\" data-end=\"1977\"\u003e\n\u003ctd data-start=\"1952\" data-end=\"1965\" data-col-size=\"sm\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1965\" data-end=\"1977\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1967\" data-end=\"1975\"\u003e0.1%\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1978\" data-end=\"2024\"\u003e\n\u003ctd data-start=\"1978\" data-end=\"1989\" data-col-size=\"sm\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1989\" data-end=\"2024\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"1991\" data-end=\"2022\"\u003e±(5% Full Scale + 5 Digits)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2026\" data-end=\"2029\"\u003e\n\u003ch2 data-section-id=\"17kul15\" data-start=\"2031\" data-end=\"2055\"\u003eMeasurement Principle\u003c\/h2\u003e\n\u003cul data-start=\"2057\" data-end=\"2256\"\u003e\n\u003cli data-section-id=\"4o4wg\" data-start=\"2057\" data-end=\"2131\"\u003eTwo stainless-steel electrode pins measure the conductivity of the soil.\u003c\/li\u003e\n\u003cli data-section-id=\"fjn2gx\" data-start=\"2132\" data-end=\"2256\"\u003eThe instrument converts conductivity into a direct soil moisture percentage reading. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2258\" data-end=\"2261\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"2263\" data-end=\"2272\"\u003eDisplay\u003c\/h1\u003e\n\u003cul data-start=\"2274\" data-end=\"2342\"\u003e\n\u003cli data-section-id=\"11bam7t\" data-start=\"2274\" data-end=\"2287\"\u003eLCD Display\u003c\/li\u003e\n\u003cli data-section-id=\"104a3so\" data-start=\"2288\" data-end=\"2318\"\u003eDisplay Size: \u003cstrong data-start=\"2304\" data-end=\"2318\"\u003e28 × 19 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13v1vef\" data-start=\"2319\" data-end=\"2342\"\u003eClear Digital Readout\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2344\" data-end=\"2347\"\u003e\n\u003ch1 data-section-id=\"972ac7\" data-start=\"2349\" data-end=\"2360\"\u003eFunctions\u003c\/h1\u003e\n\u003cul data-start=\"2362\" data-end=\"2425\"\u003e\n\u003cli data-section-id=\"17sg56d\" data-start=\"2362\" data-end=\"2389\"\u003eSoil Moisture Measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1uv1gyf\" data-start=\"2390\" data-end=\"2401\"\u003eData Hold\u003c\/li\u003e\n\u003cli data-section-id=\"1oosgcw\" data-start=\"2402\" data-end=\"2425\"\u003eLow Battery Indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2427\" data-end=\"2430\"\u003e\n\u003ch1 data-section-id=\"hq57w\" data-start=\"2432\" data-end=\"2439\"\u003eProbe\u003c\/h1\u003e\n\u003cul data-start=\"2441\" data-end=\"2547\"\u003e\n\u003cli data-section-id=\"iatl6d\" data-start=\"2441\" data-end=\"2459\"\u003eIntegrated Probe\u003c\/li\u003e\n\u003cli data-section-id=\"p7eod0\" data-start=\"2460\" data-end=\"2486\"\u003eProbe Length: \u003cstrong data-start=\"2476\" data-end=\"2486\"\u003e220 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16e1g3i\" data-start=\"2487\" data-end=\"2514\"\u003eProbe Diameter: \u003cstrong data-start=\"2505\" data-end=\"2514\"\u003e10 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9jgleb\" data-start=\"2515\" data-end=\"2547\"\u003eTwo Stainless Steel Electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2549\" data-end=\"2552\"\u003e\n\u003ch1 data-section-id=\"1grw4wg\" data-start=\"2554\" data-end=\"2569\"\u003eSampling Time\u003c\/h1\u003e\n\u003cul data-start=\"2571\" data-end=\"2602\"\u003e\n\u003cli data-section-id=\"1vugqw\" data-start=\"2571\" data-end=\"2602\"\u003eApproximately \u003cstrong data-start=\"2587\" data-end=\"2602\"\u003e0.8 seconds\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2604\" data-end=\"2607\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"2609\" data-end=\"2631\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"2633\" data-end=\"2658\"\u003e\u003cstrong data-start=\"2633\" data-end=\"2658\"\u003eOperating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2660\" data-end=\"2677\"\u003e\n\u003cli data-section-id=\"i294g6\" data-start=\"2660\" data-end=\"2677\"\u003e\u003cstrong data-start=\"2662\" data-end=\"2677\"\u003e0°C to 50°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2679\" data-end=\"2701\"\u003e\u003cstrong data-start=\"2679\" data-end=\"2701\"\u003eOperating Humidity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2703\" data-end=\"2725\"\u003e\n\u003cli data-section-id=\"1blh8n9\" data-start=\"2703\" data-end=\"2725\"\u003e\u003cstrong data-start=\"2705\" data-end=\"2725\"\u003eLess than 80% RH\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2727\" data-end=\"2730\"\u003e\n\u003ch1 data-section-id=\"90elgq\" data-start=\"2732\" data-end=\"2746\"\u003ePower Supply\u003c\/h1\u003e\n\u003cul data-start=\"2748\" data-end=\"2783\"\u003e\n\u003cli data-section-id=\"1eodmfx\" data-start=\"2748\" data-end=\"2783\"\u003e\u003cstrong data-start=\"2750\" data-end=\"2783\"\u003e4 × 1.5V AAA Batteries (UM-4)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2785\" data-end=\"2806\"\u003e\u003cstrong data-start=\"2785\" data-end=\"2806\"\u003ePower Consumption\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2808\" data-end=\"2833\"\u003e\n\u003cli data-section-id=\"g07upu\" data-start=\"2808\" data-end=\"2833\"\u003eApproximately \u003cstrong data-start=\"2824\" data-end=\"2833\"\u003e12 mA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2835\" data-end=\"2838\"\u003e\n\u003ch1 data-section-id=\"q6znlx\" data-start=\"2840\" data-end=\"2852\"\u003eDimensions\u003c\/h1\u003e\n\u003ch2 data-section-id=\"1om1dzy\" data-start=\"2854\" data-end=\"2867\"\u003eMeter Body\u003c\/h2\u003e\n\u003cul data-start=\"2869\" data-end=\"2891\"\u003e\n\u003cli data-section-id=\"1riqr30\" data-start=\"2869\" data-end=\"2891\"\u003e\u003cstrong data-start=\"2871\" data-end=\"2891\"\u003e172 × 40 × 40 mm\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"xnv40f\" data-start=\"2893\" data-end=\"2901\"\u003eProbe\u003c\/h2\u003e\n\u003cul data-start=\"2903\" data-end=\"2932\"\u003e\n\u003cli data-section-id=\"cmmpgp\" data-start=\"2903\" data-end=\"2932\"\u003e\u003cstrong data-start=\"2905\" data-end=\"2932\"\u003e220 mm × 10 mm Diameter\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"nwxl4r\" data-start=\"2934\" data-end=\"2949\"\u003eTotal Length\u003c\/h2\u003e\n\u003cul data-start=\"2951\" data-end=\"2963\"\u003e\n\u003cli data-section-id=\"uxp1io\" data-start=\"2951\" data-end=\"2963\"\u003e\u003cstrong data-start=\"2953\" data-end=\"2963\"\u003e392 mm\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2965\" data-end=\"2968\"\u003e\n\u003ch1 data-section-id=\"en4152\" data-start=\"2970\" data-end=\"2978\"\u003eWeight\u003c\/h1\u003e\n\u003cul data-start=\"2980\" data-end=\"3027\"\u003e\n\u003cli data-section-id=\"1y0vaoa\" data-start=\"2980\" data-end=\"3027\"\u003eApproximately \u003cstrong data-start=\"2996\" data-end=\"3005\"\u003e267 g\u003c\/strong\u003e (including batteries)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3029\" data-end=\"3032\"\u003e\n\u003ch1 data-section-id=\"jrwzgb\" data-start=\"3034\" data-end=\"3048\"\u003eConstruction\u003c\/h1\u003e\n\u003cul data-start=\"3050\" data-end=\"3157\"\u003e\n\u003cli data-section-id=\"lc90so\" data-start=\"3050\" data-end=\"3083\"\u003eHigh-Impact ABS Plastic Housing\u003c\/li\u003e\n\u003cli data-section-id=\"2a8v2h\" data-start=\"3084\" data-end=\"3122\"\u003eCorrosion-Resistant Metal Electrodes\u003c\/li\u003e\n\u003cli data-section-id=\"vwnvft\" data-start=\"3123\" data-end=\"3157\"\u003eMicroprocessor-Based Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3159\" data-end=\"3162\"\u003e\n\u003ch1 data-section-id=\"164r0bs\" data-start=\"3164\" data-end=\"3191\"\u003eStandard Package Includes\u003c\/h1\u003e\n\u003cul data-start=\"3193\" data-end=\"3255\"\u003e\n\u003cli data-section-id=\"9aqx17\" data-start=\"3193\" data-end=\"3229\"\u003eLutron PMS-714 Soil Moisture Meter\u003c\/li\u003e\n\u003cli data-section-id=\"acvpej\" data-start=\"3230\" data-end=\"3255\"\u003eUser Instruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3257\" data-end=\"3260\"\u003e\n\u003ch1 data-section-id=\"yknlu6\" data-start=\"3262\" data-end=\"3284\"\u003eOptional Accessories\u003c\/h1\u003e\n\u003cul data-start=\"3286\" data-end=\"3314\"\u003e\n\u003cli data-section-id=\"1ruj7hs\" data-start=\"3286\" data-end=\"3314\"\u003eHard Carrying Case (CA-06)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3316\" data-end=\"3319\"\u003e\n\u003ch1 data-section-id=\"1bym0se\" data-start=\"3321\" data-end=\"3333\"\u003eAdvantages\u003c\/h1\u003e\n\u003cul data-start=\"3335\" data-end=\"3624\"\u003e\n\u003cli data-section-id=\"j1vxsd\" data-start=\"3335\" data-end=\"3381\"\u003eQuick and Accurate Soil Moisture Measurement\u003c\/li\u003e\n\u003cli data-section-id=\"15ktj3j\" data-start=\"3382\" data-end=\"3412\"\u003eEasy-to-Read Digital Display\u003c\/li\u003e\n\u003cli data-section-id=\"1mpx1tl\" data-start=\"3413\" data-end=\"3435\"\u003eDurable Probe Design\u003c\/li\u003e\n\u003cli data-section-id=\"6q6lhq\" data-start=\"3436\" data-end=\"3462\"\u003eLightweight and Portable\u003c\/li\u003e\n\u003cli data-section-id=\"7yy8zm\" data-start=\"3463\" data-end=\"3502\"\u003eReliable for Field and Laboratory Use\u003c\/li\u003e\n\u003cli data-section-id=\"1lt0fj5\" data-start=\"3503\" data-end=\"3520\"\u003eLow Maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"kjt41f\" data-start=\"3521\" data-end=\"3542\"\u003eRugged Construction\u003c\/li\u003e\n\u003cli data-section-id=\"16cpoc9\" data-start=\"3543\" data-end=\"3570\"\u003eSimple One-Hand Operation\u003c\/li\u003e\n\u003cli data-section-id=\"cthoh5\" data-start=\"3571\" data-end=\"3590\"\u003eLong Battery Life\u003c\/li\u003e\n\u003cli data-section-id=\"8t1ojn\" data-start=\"3591\" data-end=\"3624\"\u003eIdeal for Routine Soil Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3626\" data-end=\"3629\"\u003e\n\u003ch1 data-section-id=\"yc3x49\" data-start=\"3631\" data-end=\"3650\"\u003eIndustries Served\u003c\/h1\u003e\n\u003cul data-start=\"3652\" data-end=\"3844\"\u003e\n\u003cli data-section-id=\"13ecb4p\" data-start=\"3652\" data-end=\"3665\"\u003eAgriculture\u003c\/li\u003e\n\u003cli data-section-id=\"1ao2edo\" data-start=\"3666\" data-end=\"3680\"\u003eHorticulture\u003c\/li\u003e\n\u003cli data-section-id=\"10g1wq7\" data-start=\"3681\" data-end=\"3701\"\u003eGreenhouse Farming\u003c\/li\u003e\n\u003cli data-section-id=\"8eca0e\" data-start=\"3702\" data-end=\"3715\"\u003eLandscaping\u003c\/li\u003e\n\u003cli data-section-id=\"iesvbw\" data-start=\"3716\" data-end=\"3742\"\u003eEnvironmental Monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"f6qsc4\" data-start=\"3743\" data-end=\"3766\"\u003eResearch Laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1pikjuw\" data-start=\"3767\" data-end=\"3793\"\u003eEducational Institutions\u003c\/li\u003e\n\u003cli data-section-id=\"nyea0x\" data-start=\"3794\" data-end=\"3817\"\u003eIrrigation Management\u003c\/li\u003e\n\u003cli data-section-id=\"1r99hfe\" data-start=\"3818\" data-end=\"3828\"\u003eForestry\u003c\/li\u003e\n\u003cli data-section-id=\"1hr3vzv\" data-start=\"3829\" data-end=\"3844\"\u003ePlant Science\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":46933806022829,"sku":"Lutron PMS-714","price":13777.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/7666\/9357\/files\/PMS714.webp?v=1785233769","url":"https:\/\/rinstruments.com\/products\/lutron-pms-714-digital-soil-moisture-meter-soil-moisture-tester-0-50-moisture-content-probe-type","provider":"Rinstruments","version":"1.0","type":"link"}