{"product_id":"hanna-instruments-hi98130-combo-ph-conductivity-tds-tester-high-range","title":"Hanna Instruments HI98130 Combo pH\/Conductivity\/TDS Tester | High Range | 0–14.00 pH | 0.00–20.00 mS\/cm EC | 0.00–10.00 ppt TDS | Waterproof","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eHanna Instruments HI98130\u003c\/strong\u003e is a compact, waterproof multiparameter tester designed to measure \u003cstrong\u003epH, high-range Electrical Conductivity (EC), Total Dissolved Solids (TDS), and temperature\u003c\/strong\u003e in a single handheld instrument. It eliminates the need to carry separate meters for routine water-quality testing and is particularly suitable for \u003cstrong\u003ehydroponics, aquariums, pools, ponds, water treatment and laboratory applications\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe HI98130 provides a \u003cstrong\u003epH range of 0.00 to 14.00\u003c\/strong\u003e, high-range EC measurement from \u003cstrong\u003e0.00 to 20.00 mS\/cm\u003c\/strong\u003e, and TDS measurement from \u003cstrong\u003e0.00 to 10.00 ppt (g\/L)\u003c\/strong\u003e. Both pH and EC\/TDS measurements feature automatic temperature compensation for more consistent readings. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-in-1 measurement:\u003c\/strong\u003e pH, EC, TDS and temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide pH range:\u003c\/strong\u003e 0.00–14.00 pH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-range EC:\u003c\/strong\u003e 0.00–20.00 mS\/cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-range TDS:\u003c\/strong\u003e 0.00–10.00 ppt (g\/L)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAutomatic Temperature Compensation (ATC)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable pH electrode\u003c\/strong\u003e with extractable cloth junction\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGraphite\/amperometric EC\/TDS sensor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExposed temperature probe\u003c\/strong\u003e for fast temperature response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic pH calibration:\u003c\/strong\u003e one or two points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic EC\/TDS calibration:\u003c\/strong\u003e one point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable EC-to-TDS conversion factor:\u003c\/strong\u003e 0.45–1.00\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable temperature compensation coefficient:\u003c\/strong\u003e 0.0–2.4%\/°C\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWaterproof and floating design\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge LCD\u003c\/strong\u003e with stability and low-battery indicators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHOLD function\u003c\/strong\u003e for freezing readings on the display\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBattery Error Prevention System (BEPS)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic shut-off\u003c\/strong\u003e after 8 minutes of inactivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact pocket-sized design\u003c\/strong\u003e for field and laboratory use \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer TyagGW_tableContainerWithTableOfContents\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eHI98130\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHanna Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI98130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCombo pH\/EC\/TDS Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiparameter Testers \/ Testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00–14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, 1 or 2 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Buffer Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.01 \/ 7.01 \/ 10.01 or 4.01 \/ 6.86 \/ 9.18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00–20.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, 1 point at 12.88 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00–10.00 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, 1 point at 6.44 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC\/TDS Temperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0–2.4%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC-to-TDS Conversion Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45–1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0–60.0°C \/ 32.0–140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ ±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI73127, replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 × 1.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Shut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–50°C; RH max. 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e163 × 40 × 26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eReplaceable pH Electrode\u003c\/h2\u003e\n\u003cp\u003eThe HI98130 comes with the \u003cstrong\u003eHI73127 replaceable pH electrode\u003c\/strong\u003e. Its extractable cloth junction can help extend electrode life, while the snap-in connection makes electrode replacement straightforward. This means the complete tester does not need to be replaced when the pH electrode reaches the end of its service life. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eHigh-Range EC and TDS Measurement\u003c\/h2\u003e\n\u003cp\u003eUnlike the \u003cstrong\u003eHI98129 low-range model\u003c\/strong\u003e, the HI98130 is designed for higher conductivity and TDS applications. It measures EC up to \u003cstrong\u003e20.00 mS\/cm\u003c\/strong\u003e and TDS up to \u003cstrong\u003e10.00 ppt (g\/L)\u003c\/strong\u003e, making it suitable for applications where a low-range tester may not provide sufficient measurement capability. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe EC-to-TDS conversion factor can be adjusted from \u003cstrong\u003e0.45 to 1.00\u003c\/strong\u003e, allowing the meter to be configured according to the requirements of the application. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eGraphite EC\/TDS Sensor\u003c\/h2\u003e\n\u003cp\u003eThe HI98130 uses an \u003cstrong\u003eamperometric conductivity\/TDS sensor\u003c\/strong\u003e designed for reliable high-range measurements. Hanna states that its graphite conductivity probe resists contamination from salt deposits, while the exposed temperature sensor provides a fast response for temperature-compensated readings. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eAutomatic Temperature Compensation\u003c\/h2\u003e\n\u003cp\u003eTemperature affects both pH and conductivity measurements. The HI98130 automatically compensates readings for temperature variations. The temperature can be displayed in \u003cstrong\u003e°C or °F\u003c\/strong\u003e, while the EC\/TDS temperature compensation coefficient can be adjusted from \u003cstrong\u003e0.0 to 2.4%\/°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eEasy Calibration\u003c\/h2\u003e\n\u003cp\u003eThe HI98130 provides automatic calibration for all major measurement functions:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003epH Calibration:\u003c\/strong\u003e\u003cbr\u003eAutomatic one- or two-point calibration using standard pH buffers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEC Calibration:\u003c\/strong\u003e\u003cbr\u003eAutomatic one-point calibration at \u003cstrong\u003e12.88 mS\/cm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTDS Calibration:\u003c\/strong\u003e\u003cbr\u003eAutomatic one-point calibration at \u003cstrong\u003e6.44 ppt (g\/L)\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHanna HI98130\u003c\/strong\u003e is suitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydroponics\u003c\/li\u003e\n\u003cli\u003eAquariums\u003c\/li\u003e\n\u003cli\u003eSwimming pools\u003c\/li\u003e\n\u003cli\u003ePonds\u003c\/li\u003e\n\u003cli\u003eWater treatment\u003c\/li\u003e\n\u003cli\u003eWater-quality testing\u003c\/li\u003e\n\u003cli\u003eAgriculture and irrigation\u003c\/li\u003e\n\u003cli\u003eLaboratory applications\u003c\/li\u003e\n\u003cli\u003eEnvironmental monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial water testing\u003c\/li\u003e\n\u003cli\u003eGeneral pH, EC and TDS measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHanna specifically lists \u003cstrong\u003ehydroponics, aquariums, pools and ponds\u003c\/strong\u003e among the intended applications for this tester. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cp\u003eThe HI98130 is supplied with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHI98130 Combo pH\/EC\/TDS Tester\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHI73127 replaceable pH electrode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHI73128 electrode removal tool\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003epH 4.01 buffer solution\u003c\/li\u003e\n\u003cli\u003epH 7.01 buffer solution\u003c\/li\u003e\n\u003cli\u003epH electrode storage solution\u003c\/li\u003e\n\u003cli\u003epH electrode cleaning solution\u003c\/li\u003e\n\u003cli\u003e12.88 mS\/cm conductivity standard\u003c\/li\u003e\n\u003cli\u003e6.44 ppt TDS standard\u003c\/li\u003e\n\u003cli\u003e4 × 1.5V batteries\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate\u003c\/li\u003e\n\u003cli\u003eInstruction manual \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose Hanna HI98130?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHI98130\u003c\/strong\u003e is an excellent choice for customers looking for a \u003cstrong\u003esingle portable instrument for high-range pH, EC and TDS testing\u003c\/strong\u003e. Its waterproof construction, replaceable pH electrode, graphite EC\/TDS sensor, automatic temperature compensation and simple calibration make it suitable for both routine professional and field measurements.\u003c\/p\u003e","brand":"HAANA","offers":[{"title":"Default Title","offer_id":47445269020845,"sku":"90275090","price":18055.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/7666\/9357\/files\/hi98130-2016.jpg?v=1788949762","url":"https:\/\/rinstruments.com\/products\/hanna-instruments-hi98130-combo-ph-conductivity-tds-tester-high-range","provider":"Rinstruments","version":"1.0","type":"link"}