{"product_id":"aquasol-digital-apcodm1-cod-meter-chemical-oxygen-demand-cod-testing-meter-digital-cod-photometer-for-water-wastewater-analysis","title":"AQUASOL DIGITAL APCODM1 COD Meter | Chemical Oxygen Demand (COD) Testing Meter | Digital COD Photometer for Water \u0026 Wastewater Analysis","description":"\u003ch3 dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eShort Description\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eAQUASOL DIGITAL APCODM1 Portable COD Meter\u003c\/strong\u003e is a microprocessor-based instrument designed for fast and convenient measurement of \u003cstrong\u003eChemical Oxygen Demand (COD)\u003c\/strong\u003e in water and wastewater. It uses a \u003cstrong\u003eclosed reflux method\u003c\/strong\u003e, supports standard vial sizes, and provides three measurement ranges up to \u003cstrong\u003e15,000 mg\/L\u003c\/strong\u003e. The compact meter features a large LCD display and memory\/storage functionality, making it suitable for on-site and laboratory COD testing.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor-based\u003c\/strong\u003e COD measurement\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003efast, reliable and accurate measurements\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWide measurement range up to 15,000 mg\/L\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThree COD ranges:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow:\u003c\/strong\u003e 3–150 mg\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedium:\u003c\/strong\u003e 20–1,500 mg\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh:\u003c\/strong\u003e 200–15,000 mg\/L\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSEPA-compliant closed reflux method\u003c\/strong\u003e, as stated in the supplied product specification\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003estandard vial size\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eWavelength range: \u003cstrong\u003e420–610 nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFast response time of \u003cstrong\u003eless than 3 seconds\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLarge LCD display for convenient reading\u003c\/li\u003e\n\u003cli\u003eMemory and storage function\u003c\/li\u003e\n\u003cli\u003eCompact ABS housing\u003c\/li\u003e\n\u003cli\u003eSuitable for on-site and laboratory COD analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe broader AQUASOL product literature also describes its portable COD meter range as intended for wastewater and freshwater applications, including ponds and lakes. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2 dir=\"auto\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAQUASOL DIGITAL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAPCODM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOD – Chemical Oxygen Demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstrument Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePortable COD Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Reflux Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3–150 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMedium Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–1,500 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–15,000 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 15,000 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420–610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±3% FS below 1,500 mg\/L; ±5% FS above 1,500 mg\/L*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3 seconds*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMemory \u0026amp; storage function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVial Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard vial size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAAA 1.5 V × 4 batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 × 135 × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeter Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e168 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003e \u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003e\u003c\/h2\u003e\n\u003ch2 dir=\"auto\"\u003eApplications\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe APCODM1 can be used for COD monitoring in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWastewater treatment plants\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSTP – Sewage Treatment Plants\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eETP – Effluent Treatment Plants\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIndustrial wastewater\u003c\/li\u003e\n\u003cli\u003eEnvironmental laboratories\u003c\/li\u003e\n\u003cli\u003eWater-quality laboratories\u003c\/li\u003e\n\u003cli\u003eFreshwater monitoring\u003c\/li\u003e\n\u003cli\u003ePond and lake water analysis\u003c\/li\u003e\n\u003cli\u003eFood \u0026amp; beverage industries\u003c\/li\u003e\n\u003cli\u003ePharmaceutical industries\u003c\/li\u003e\n\u003cli\u003eChemical industries\u003c\/li\u003e\n\u003cli\u003eTextile industries\u003c\/li\u003e\n\u003cli\u003eResearch laboratories\u003c\/li\u003e\n\u003cli\u003eEnvironmental monitoring\u003c\/li\u003e\n\u003cli\u003ePollution-control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eAQUASOL's published materials identify COD testing applications in wastewater and freshwater and describe the instrument as suitable for on-site and laboratory analysis. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2 dir=\"auto\"\u003eHow It Works\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003ePrepare the water\/wastewater sample using the appropriate COD digestion vial\/reagent.\u003c\/li\u003e\n\u003cli\u003eDigest the sample according to the applicable COD testing procedure.\u003c\/li\u003e\n\u003cli\u003ePlace the prepared standard COD vial into the meter.\u003c\/li\u003e\n\u003cli\u003eSelect the appropriate COD measurement range.\u003c\/li\u003e\n\u003cli\u003eThe meter performs the photometric measurement.\u003c\/li\u003e\n\u003cli\u003eThe COD result is displayed on the LCD.\u003c\/li\u003e\n\u003cli\u003eResults can be retained using the meter's memory\/storage function.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp dir=\"auto\"\u003eThe AQUASOL COD system is based on closed-reflux COD measurement using standard-size vials. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2 dir=\"auto\"\u003eBenefits\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003ePortable Testing:\u003c\/strong\u003e Convenient for on-site water and wastewater analysis.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eWide COD Range:\u003c\/strong\u003e Three ranges cover low-, medium- and high-COD samples up to 15,000 mg\/L.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eFast Measurement:\u003c\/strong\u003e The published APCOD series specification gives a response time of less than 3 seconds. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eEasy Operation:\u003c\/strong\u003e Large LCD display and straightforward digital measurement.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eReduced Handling:\u003c\/strong\u003e Closed-vial testing avoids the traditional open-reflux titration approach described in AQUASOL literature. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2 dir=\"auto\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eStandard product package may include:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 × AQUASOL DIGITAL APCODM1 COD Meter\u003c\/li\u003e\n\u003cli\u003eCOD testing accessories, as applicable\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eBattery\/power accessories as applicable\u003c\/li\u003e\n\u003cli\u003eCarrying\/storage accessories, if included in the supplied package\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003e \u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"AQUASOL DIGITAL","offers":[{"title":"Default Title","offer_id":47643897692333,"sku":"APCODM1","price":52000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/7666\/9357\/files\/rn-image_picker_lib_temp_204539fe-ce9f-409c-ae28-d3550ac7908f.jpg?v=1789874849","url":"https:\/\/rinstruments.com\/products\/aquasol-digital-apcodm1-cod-meter-chemical-oxygen-demand-cod-testing-meter-digital-cod-photometer-for-water-wastewater-analysis","provider":"Rinstruments","version":"1.0","type":"link"}